sub categories Products
-
Bench Instruments
show subcategories for Bench Instruments -
Data loggers / DAQ
show subcategories for Data loggers / DAQ -
EMC – EMI (Emission)
show subcategories for EMC – EMI (Emission) -
EMC – EMS (Immunity)
show subcategories for EMC – EMS (Immunity) -
Photovoltaics
show subcategories for Photovoltaics -
Handheld Instruments
show subcategories for Handheld Instruments- Battery Test Instruments
- Relay
- Cable Locators / Cable Tester
- Circuit Breaker
- Clamp Meters
- ESD Test Instruments
- Earth Testers
- Electrical Quality Instruments
- Electrical Safety Tester
- Electrical Testers
- Environmental Instruments
- Fiber Instruments
- Fordonstestinstrument
- Installation Testers
- Insulation Testers
- Multimeters
- Network Tester
- Ohm Testers
- Power Meters
- Process Instruments
- RF Instruments
- Thermal Cameras
-
High Voltage Products
show subcategories for High Voltage Products -
Power Products
show subcategories for Power Products -
Oscilloscopes
show subcategories for Oscilloscopes -
PC Instrument
show subcategories for PC Instrument -
Rolling Tables and Wagons
show subcategories for Rolling Tables and Wagons -
Accessories
show subcategories for Accessories -
Sale
For Oscilloscopes
Instruments for current measurement with connection to oscilloscopes and test systems. The range includes current probes for AC and DC measurement for analysis, verification and troubleshooting.
product listing
Observe:
Chauvin Arnoux D38N Current Clamp
Art.no 1654AC currents up to 9,000 A, high accuracy up to 3,000 A, wide frequency range, BNC connection and voltage output 1/10/100 mV/A.
Chauvin Arnoux E27 Current Clamp
Art.no 2457AC/DC current clamp, 50 mA–100 A measurement range, DC–100 kHz bandwidth, 1 mV/mA and 10 mV/A output via insulated BNC and CAT III 600 V / CAT IV 300 V.
Chauvin Arnoux MH60 Clamp Meter
Art.no 2103Measuring range 10 mA–100 A AC/DC with 1 MHz bandwidth, BNC output for oscilloscopes, 26 mm jaw opening, rechargeable battery and selectable filters 3 kHz/30 kHz.
Chauvin Arnoux MiniFlex MA200 Mini Current Sensor
Art.no 1130Flexible AC current sensor 0.5 A–3 kA with Rogowski coil, 1 MHz bandwidth, 3 V output signal and 17 cm measuring loop with BNC connection.
Chauvin Arnoux MiniFlex MA200 Current Sensor
Art.no 1129Flexible AC current sensor 0.5 A–3 kA with Rogowski coil, 1 MHz bandwidth, 3 V output signal and 25 cm measuring loop with BNC connection.
Chauvin Arnoux MiniFlex MA200 Current Sensor
Art.no 2004Flexible AC current sensor 0.5 A–3 kA with Rogowski coil, 1 MHz bandwidth, 3 V output signal and 35 cm measuring loop with BNC connector.
Chauvin Arnoux Y7 Current Clamp
Art.no 1526AC current clamp, 1–500 A range (1200 A peak), 10 mV/A output via BNC, 5 Hz–10 kHz bandwidth and 1.5 m double-insulated cable.
Fluke I1000S Current Clamp
Art.no 1199AC current clamp for oscilloscopes with a measurement range up to 1000 A, 5 Hz–100 kHz bandwidth, passive filter for harmonics and BNC output for direct connection.
Fluke I200S AC Current Clamp
Art.no 1201AC current clamp with 20 A/200 A measurement range, 10 mV/A and 100 mV/A output, BNC connection, frequency range 40 Hz–10 kHz and CAT III 600 V.
Fluke I3000S Flex-24 AC Flexible Current Clamp
Art.no 1211AC flexible current probe based on the Rogowski principle, 30 A/300 A/3000 A measurement range, 1/10/100 mV/A output, 610 mm flexible loop and CAT III 600 V.
Fluke I3000S Flex-36 AC Flexible Current Probe
Art.no 1212AC Rogowski-type current probe, 30 A/300 A/3000 A measurement range, 1/10/100 mV/A output, 915 mm flexible loop and CAT III 600 V.
Fluke I3000S Clamp Meter
Art.no 1202AC current clamp for oscilloscopes and DMM, up to 3000 A, 10 Hz–100 kHz bandwidth, BNC output via adapter for power distribution.
Fluke I30S Current Clamp
Art.no 1644AC/DC current clamp with Hall-effect sensor, 30 mA–30 A range, DC–100 kHz bandwidth, BNC output and CAT III 300 V.
Fluke I310S Current Probe
Art.no 1348Hall-effect current probe for AC/DC, 30 A/300 A range, ±45 A/450 A DC, 10 mV/A–1 mV/A output, DC–20 kHz bandwidth and battery operation.
Fluke I400S AC Clamp Meter
Art.no 1204Two measurement ranges 40 A and 400 A AC with 10/1 mV/A output, BNC connection for oscilloscopes and power quality meters, CAT IV 600 V / CAT III 1000 V.
PEM CWT Mini AC Current Probe
Art.no 1216Rogowski current probe with compact coil, Hz–MHz bandwidth, 60 A–300 kA peak current, low droop and predictable phase response for 50/60 Hz and pulse measurements.
PEM CWT Current Probe
Art.no 1218Rogowski current probe with 0.1 Hz–16 MHz bandwidth, 600 A–60 kA peak current, 40 kA/µs di/dt, 10 kV insulation and flexible clamp coil.
PEM CWT Ultra Mini Current Probe
Art.no 1217Rogowski current probe with 1.6 mm thin coil, Hz–30 MHz bandwidth, 30 A–30 kA peak current, up to 100 kA/µs di/dt and BNC output.
PEM DCFlex Current Coil For DC Measurement
Art.no 1625DC current probe for temporary measurements, 2–40 kA, single-shot with ±1% accuracy and analogue BNC output for DMM or oscilloscope.
PEM LFR AC Current Probe With Two Measurement Ranges
Art.no 1219Flexible AC current probe with two ranges, low phase shift at low frequencies and wide dynamic range, for power quality, leakage and earth current measurement.
Pico TA167 Current Clamp
Art.no 2321Measuring range 200/2000 A AC/DC with BNC output, output sensitivity 10/1 mV/A, overload capacity 2200 A and accurate current measurement up to 2 kA.
Rigol RP1001C Current Probe
Art.no 1620AC/DC measurement up to 100 A peak (70 A RMS), DC–300 kHz bandwidth, BNC output, for conductors up to 11 mm, and battery or mains adapter operation.
Rigol RP1002C Current Probe
Art.no 1621AC/DC measurement up to 70 A peak, DC–1 MHz bandwidth, BNC output, for conductors up to 11 mm, and battery or mains adapter operation.